With a wide range of Rolegard security roller shutters to choose from we can match the ideal solution to your application needs. For easy identification Rolegard model numbers are described by their security rating, curtain profile and drive configuration.  Extensive experience in the design and installation of security roller shutters across various industries means we are exceptionally well equipped to support you. For further advice and technical drawings please contact us

Rolegard SR5-B

Combining the highest physical attack standard achieved in a security roller shutter with unrivalled ballistics and blast protection properties, Rolegard SR5-B has been tested against a wide range of professional attack methods including high end power tools. Designed for very high risk applications the Rolegard SR5-B security shutter features a reinforced double skin and heavy duty curtain profile with flat faced profiles. Ballistics rated to FB4 (FB3 as standard) and incorporating our unique Automatic Self Locking system (ASL) which significantly improves protocol and prevents lifting or jacking of the roller shutter in the closed position.

Security Standard:LPS1175, Issue 7, Level 5
Locking:Automatic Self Locking (ASL)
Drive Motor:Heavy Duty Chain Drive or Direct Drive
Ballistics:FB3 Standard (up to FB4)
Blast performance:Up to 3kpa (Conditions apply)
Wind pressure:Class 5 (Beaufort 13, 93mph, 1000N/m2)
Min. Support Structure:Reinforced concrete / Steel work
Max. Area:64Sq/M
Security Standard:LPS1175, Issue 7, Level 4
Locking:Automatic Self Locking (ASL)
Drive Motor:Heavy Duty Chain Drive or Direct Drive
Blast performance:Up to 3kpa (Conditions apply)
Wind pressure:Class 5 (Beaufort 13, 93mph, 1000N/m2)
Min. Support Structure:Reinforced concrete / Steel work
Max. Area:64Sq/M

Rolegard SR4-DS-HD

Designed to target harden buildings with a very high security threat. Double-skin heavy duty curtain profile reinforced for maximum resistance. Suitable for military, government, critical national infrastructure, banking, manufacturing, high risk commercial premises and other applications. Featuring our unique Automatic Self Locking (ASL) technology for locking down properties without the need for secondary locks. Suitable for exposed locations that may face high wind pressures up to hurricane force and has the additional benefit of blast resistance. Optional tested stainless steel profiles.

Rolegard SR4-SS-HD

Providing security for high risk applications. Special single-skin heavy duty profiles are used to create a ‘fully scaled’ roller shutter. Suitable for government, critical national infrastructure, banking, manufacturing, high risk commercial premises and other applications. Mechanical padlockable shoot bolts with optional upgrade to electronic locking bolts. Suitable for exposed locations that may face high wind pressures up to hurricane force. Optional tested stainless steel profiles.

Security Standard:LPS1175, Issue 7, Level 4
Locking:Mechanical Padlockable Shoot Bolts
Optional Electric bolts
Drive Motor:Heavy Duty Chain Drive or Direct Drive
Wind pressure:Class 5 (Beaufort 13, 93mph, 1000N/m2)
Min. Support Structure:Reinforced concrete / Steel work
Max. Area:64Sq/M
Security Standard:LPS1175, Issue 7, Level 3
Locking:Mechanical Padlockable Shoot Bolts
Optional Electronic bolts
Drive Motor:Heavy Duty Chain Drive or Direct Drive
Thermal insulation:U=4.4W/m2.k
Wind pressure:Class 5 (Beaufort 13, 93mph, 1000N/m2)
Min. Support Structure:Dense concrete block
Max. Area:64Sq/M

Rolegard SR3-INS

Providing security against experienced forced entry in high risk applications our SR3 insulated model also adds thermal and acoustic performance. Double skin, heavy duty flat faced profiles are used with an insulated core to reduce energy loss from buildings and help retain internal temperature. Acoustic performance helps to reduce noise levels in sensitive areas. Hurricane level wind protection ensures suitability for transport, critical national infrastructure and other exposed locations. The steel side guides and aluminium bottom profile of the security roller shutters incorporate twin brush seals and a rubber bottom weather seal.

Rolegard SR3-SS

The Rolegard SR3 shutter provides security against experienced force entry in high risk applications such as utilities, transport, critical national infrastructure, manufacturing and commercial premises. The shutter construction is of a galvanised steel, single skin, heavy gauge concave profile with reinforced side guides and bottom profile. SR3 incorporates a direct drive motor or tubular motor for less intensive applications, standard safety features are incorporated and there is a choice of activation modules.

Security Standard:LPS1175, Issue 7, Level 3
Locking:Automatic Self Locking
Optional Electric bolts
Drive Motor:Direct Drive or Tubular Motor
Min. Support Structure:Dense concrete block
Max. Area:50Sq/M
Security Standard:LPS1175, Issue 7, Level 2
Locking:Mechanical Key Operated Cylinder Lock
Drive Motor:Direct Drive or Tubular Motor
Thermal insulation:U=3.8W/m2.k
Min. Support Structure:Brick and Block
Max. Area:64Sq/M

Rolegard SR2-INS

Providing security for medium risk determined / opportunist attack our SR2 insulated model also comes with thermal and acoustic performance. The curtain construction consists of a steel foam-filled profile which is coated in Galfan, a zinc aluminium finish with high corrosion resistance. Both faces are formed with an attractive curved micro-ribbed appearance. The reinforced galvanised steel side guides and aluminium bottom profile incorporate twin brush seals and rubber bottom weather seal. Optional high speed operation – contact us for details.

Rolegard SR2-SS

Providing security for medium risk determined opportunist attack, the Rolegard SR2 security shutter is constructed of a galvanised steel, single skin, heavy gauge with a concave curtain profile, reinforced side guides and bottom profile. A mechanical key operated cylinder lock is incorporated as standard. SR2 shutters can be installed to a wide range of existing facilities as well as new buildings without additional structural work. A wide range of surface finishes enables subtle integration into a variety of building facades.

Security Standard:LPS1175, Issue 7, Level 2
Locking:Mechanical Key Operated Cylinder Lock
Drive Motor:Direct Drive or Tubular Motor
Min. Support Structure:Brick and Block
Max. Area:64Sq/M

Download the Rolegard Security Roller Shutter Brochure